KM Research Hub
← 返回论文库
无 KM 图 入排:排除 图源:可得 入排置信度 0.98

Exploring Trial Endpoints in Geographic Atrophy Based on Localized Functional Changes in Microperimetry and AI-Quantified OCT Biomarkers.

Klaudia Birner, Julia Mai, Daniela Boryshchuk, Florian Frommlet, Marie Louise Enzendorfer, Simon Schürer-Waldheim, Markus Gumpinger, Wolf-Dieter Vogl, Oliver Leingang, Stefan Sacu, Ursula Schmidt-Erfurth

Invest Ophthalmol Vis Sci 67(1) 22

PMID41533918
PMCIDPMC12805968
DOI10.1167/iovs.67.1.22
发表日期2026-01-14
入排依据:未发现恶性肿瘤人群证据。
疑似漏检:论文标题/摘要/图注含 OS/PFS/DFS/EFS/survival 等生存终点信号,但当前未得到 KM 提取结果。 已检查 4 张 PMC Figure,均未识别为 KM 图:Figure 1.:非 KM 图;Figure 2.:非 KM 图;Figure 3.:非 KM 图;Figure 4.:非 KM 图。
摘要

摘要

PURPOSE: The introduction of novel therapeutics for geographic atrophy (GA) highlights the need to define functional correlates of high-risk optical coherence tomography (OCT) biomarkers, in particular retinal-pigment-epithelium (RPE) loss and ellipsoid zone (EZ) loss. We conducted a pointwise structure/function correlation between OCT-based markers and retinal sensitivity (RS) in microperimetry (MP) in GA. METHODS: Patients from the phase III OAKS clinical trial (NCT03525613) examined by OCT (Heidelberg Spectralis) and Macular Integrity Assessment (MAIA, iCare, and Centervue) MP in a 68-point grid were analyzed. Deep-learning-(DL)-based algorithms quantified RPE, EZ loss, and EZ thickness from OCT. Co-registration between MP and OCT was established between each MP stimulus and OCT B-scan location. A multivariable mixed effect model was implemented to identify RS for each OCT biomarker, accounting for eccentricity. RESULTS: Six hundred seventy-eight study and fellow eyes of 406 patients with 41,925 MP points were included. Mean RS was 17 ± 7 decibel (dB), 9 ± 7 dB, and 2 ± 6 dB in intact retina, EZ, and RPE loss, respectively. Increased EZ thickness improved RS by 0.2 dB/µm (95% confidence interval [CI] = 0.2 to 0.2, P < 0.001). In areas of EZ loss, RS was significantly reduced compared to intact retina (-8 dB, 95% CI = -9 to -8]), whereas RPE loss decreased RS by -14 dB (95% CI = -15 to -14), accounting for eccentricity (all P < 0.001). CONCLUSIONS: A significant association between RS in MP and EZ and RPE loss on OCT was established using DL. A reliable quantitative structure/function association provides the base for developing functional endpoints in clinical care and approval of novel therapeutics for GA.

KM 提取结果

0 个 Figure · 0 个 KM 面板

尚未提取到 KM 面板。
其他 Figure(4,默认折叠)

这些图片未产生 KM 曲线结果,不在主页面重复展示。

Figure 1.Correlation between deep learning–based OCT biomarkers and RS in dB . The OCT volume was acquired within a 20 × 20 degrees (6 × 6 mm) region ( yellow frame on NIR in the top row ) of the 30 × 30 degrees (9 × 9 mm) Spectralis OCT scan. RS values are spatially registered to the OCT volume and linked to the corresponding biomarker (EZ loss in green and RPE loss in blue ). Reduced RS is observed within EZ and RPE loss areas. Top row: Spectralis NIR image and the corresponding central B-scan shown with and without automated segmentation of EZ ( green ) and RPE loss ( blue ). Middle row: En face maps of EZ and RPE loss area derived from volumetric segmentation in each respective B-scan, along with an EZ thickness heatmap (thickness scale ranging from 0–35 µm) derived from EZ thickness measurement in each B-scan. Bottom row: MAIA MP NIR image with the fixed 68-point test grid ( left ), the respective RS values in dB superimposed to the en face map of EZ and RPE loss area ( middle ), and a scale-based visualization of RS in dB ( right ). dB, decibel; DL, deep-learning; EZ, ellipsoid zone; MP, microperimetry; NIR, near infrared reflectance; OCT, optical coherence tomography; RPE, retinal pigment epithelium; RS, retinal sensitivity.
非 KM Figure
Figure 2.Left: Bar chart illustrating the total number of MP stimuli per category, including a breakdown of all exclusions, resulting in 41,925 MP stimuli available for final analysis: 25,713 within intact retina, 4271 within EZ loss, and 11,941 within RPE loss. Right: Boxplots showing retinal sensitivity values for each OCT category.
非 KM Figure
Figure 3.Interaction plot between the metric predictor retinal sensitivity within the factor OCT category (RPE loss, EZ loss, and intact retina) correlated to retinal eccentricity (mm).
非 KM Figure
Figure 4.Box plots of retinal sensitivity in dB within intact retina (EZ thickness >20 µm), EZ thickness ≤20 µm (partial EZ loss) and EZ thickness 0 µm (EZ loss).
非 KM Figure