KM Research Hub
← 返回论文库
无 KM 图 入排:排除 图源:开放图源暂不可得 入排置信度 0.98

Left Ventricular Unloading in High-Risk Percutaneous Coronary Intervention.

Divaka Perera, Matthew Ryan, Saad M Ezad, Sohail Q Khan, Ian Webb, Peter D O'Kane, Roshan Weerackody, Matthew Dodd, Matthew Kwok, Lynn Laidlaw, Laura Van Dyck, Benjamin Wrigley, Julian W Strange, Alan Bagnall, Farzin Fath-Ordoubadi, Vasileios F Panoulas, Andrew Ladwiniec, John R Davies, Alexander Chase, Colum G Owens, Stuart Watkins, Haseeb Rahman, Nilesh Pareek, Krishnaraj Rathod, John Rawlins, Richard Evans, Stephen P Hoole, Rod H Stables, Nick Curzen, Tim Clayton, CHIP-BCIS3 Investigators

N Engl J Med 394(18) 1779-1789

PMID41910380
PMCID-
DOI10.1056/NEJMoa2515704
发表日期2026-03-30
入排依据:未发现恶性肿瘤人群证据。
PubMed 未展示 Figure,且无可用 PMC 全文;如需图片,需要从出版社页面获取。
摘要

摘要

BACKGROUND: Complex percutaneous coronary intervention (PCI) in patients with severely impaired left ventricular function carries a high risk of death and complications. Whether percutaneous left ventricular unloading improves outcomes remains unclear. METHODS: We randomly assigned 300 patients with severe left ventricular dysfunction and extensive coronary artery disease in a 1:1 ratio to a strategy of elective unloading with a microaxial flow pump or to standard care during planned complex PCI. The primary outcome was a hierarchical composite that included death from any cause, disabling stroke, spontaneous myocardial infarction, hospitalization for cardiovascular causes, or periprocedural myocardial injury at a minimum of 12 months, as analyzed according to a win ratio. RESULTS: A total of 148 patients were assigned to receive a microaxial flow pump and 152 to receive standard care. At a median of 22 months (interquartile range, 16 to 30), 36.6% of pairwise comparisons favored the microaxial flow pump, and 43.0% favored standard care (win ratio, 0.85; 95% confidence interval [CI], 0.63 to 1.15; difference, -6.4 percentage points; P = 0.30). Death from any cause occurred in 47 patients in the microaxial-flow-pump group and 33 in the standard-care group (hazard ratio, 1.54; 95% CI, 0.99 to 2.41). There was no material between-group difference in the risk of bleeding or vascular complications. CONCLUSIONS: Among patients with severely impaired left ventricular function undergoing complex PCI, elective left ventricular unloading with a microaxial flow pump did not reduce the risk of major adverse clinical outcomes at a minimum of 12 months. (Funded by the U.K. National Institute for Health and Care Research; CHIP-BCIS3 ClinicalTrials.gov number, NCT05003817.).

KM 提取结果

0 个 Figure · 0 个 KM 面板

尚未提取到 KM 面板。