KM Research Hub
← 返回论文库
待处理 入排:排除 图源:待检查 入排置信度 0.85

The role of warm ischemia time on functional outcomes after robotic partial nephrectomy: a radionuclide renal scan study from the clock randomized trial.

Alessan Dro Antonelli, Luca Cindolo, Marco Sandri, Alessandro Veccia, Filippo Annino, Francesco Bertagna, Fabrizio Di Maida, Antonio Celia, Carlo D'Orta, Bernardino De Concilio, Maria Furlan, Valentina Giommoni, Manuela Ingrosso, Andrea Mari, Roberto Nucciotti, Catia Olianti, Angelo Porreca, Giulia Primiceri, Luigi Schips, Francesco Sessa, Pierluigi Bove, Claudio Simeone, Andrea Minervini, AGILE Group (Italian Group for Advanced Laparo-Endoscopic Surgery)

World J Urol 41(5) 1337-1344

PMID37085644
PMCIDPMC10188582
DOI10.1007/s00345-023-04366-3
发表日期2023-04-21
入排依据:The record describes a Phase 3 RCT with original results, but it evaluates a surgical procedure for functional outcomes, not a drug intervention with a time-to-event efficacy endpoint.
摘要

摘要

PURPOSE: To evaluate the relationship between warm ischemia time (WIT) duration and renal function after robot-assisted partial nephrectomy (RAPN). METHODS: The CLOCK trial is a phase 3 randomized controlled trial comparing on- vs off-clamp RAPN. All patients underwent pre- and postoperative renal scintigraphy. Six-month absolute variation of eGFR (AV-GFR), rate of relative variation in eGFR over 25% (RV-GFR > 25), absolute variation of split renal function (SRF) at scintigraphy (AV-SRF). The relationships WIT/outcomes were assessed by correlation graphs and then modeled by uni- and multivariable regression. RESULTS: 324 patients were included (206 on-clamp, 118 off-clamp RAPN). Correlation graphs showed a threshold on WIT equal to 10 min. The differences in outcome measures between cases with WIT < vs ≥ 10 min were: AV-GFR - 3.7 vs - 7.5 ml/min (p < 0.001); AV-SRF - 1% vs - 3.6% (p < 0.001); RV-GFR > 25 9.3% vs 17.8% (p = 0.008). Multivariable models found that AV-GFR was related to WIT ≥ 10 min (regression coefficient [RC] - 0.52, p = 0.019), age (RC - 0.35, p = 0.001) and baseline eGFR (RC - 0.30, p < 0.001); RV-GFR > 25 to WIT ≥ 10 min (odds ratio [OR] 1.11, p = 0.007) and acute kidney injury defined as > 50% increase in serum creatinine (OR 19.7, p = 0.009); AV-SRF to WIT ≥ 10 min (RC - 0.30, p = 0.018), baseline SRF (RC - 0.76, p < 0.001) and RENAL score (RC - 0.60. p = 0.028). The main limitation was that the CLOCK trial was designed on a different endpoint and therefore the present analysis could be underpowered. CONCLUSIONS: Up to 10 min WIT had no consequences on functional outcomes. Above the 10-min threshold, a statistically significant, but clinically negligible impact was found.

KM 提取结果

0 个 Figure · 0 个 KM 面板

尚未提取到 KM 面板。