KM Research Hub
← 返回论文库
待处理 入排:排除 图源:待检查 入排置信度 0.80

Volume matters: Breast induration is associated with irradiated breast volume in the Danish Breast Cancer Group phase III randomized Partial Breast Irradiation trial.

Mette S Thomsen, Jan Alsner, Hanne M Nielsen, Erik H Jakobsen, Mette H Nielsen, Mette Møller, Anders N Pedersen, Esben Yates, Martin Berg, Ebbe Lorenzen, Ingelise Jensen, Mirjana Josipovic, Jens Overgaard, Birgitte V Offersen, DBCG RT Committee

Radiother Oncol 177 231-235

PMID36265685
PMCID-
DOI10.1016/j.radonc.2022.09.024
发表日期2022-10-20
入排依据:The study meets oncology, human, randomized, and Phase III criteria, but it does not meet the required drug intervention or time-to-event efficacy endpoint criteria. The intervention is a non-drug radiotherapy technique, and the primary reported outcome is a toxicity measure (breast induration), not a time-to-event efficacy endpoint.
摘要

摘要

The relation between breast induration grade 2-3 at 3 years after radiation therapy and irradiated breast volume was investigated for patients in the Danish Breast Cancer Group (DBCG) Partial Breast Irradiation (PBI) trial. METHODS Treatment plan data was obtained from the Danish radiotherapy plan database. Dosimetric parameters for breast and organs at risk were determined. Breast induration data was obtained from the DBCG database. The volume of the whole breast (CTVp_breast) treated to various dose levels was determined for treatment plans in both arms. Logistic regression was used to assess the frequency of induration on breast volume irradiated to ≥40 Gy. RESULTS PBI and WBI was given to 433 and 432 patients, respectively. Median and interquartile ranges (IQR) for CTVp_breast were 710 mL (467-963 mL; PBI) and 666 mL (443-1012 mL; WBI) (p = 0.98). Median and IQR for CTVp_breast treated to ≥40 Gy was 24.9% (18.6-32.6%; PBI) and 59.8% (53.6-68.5%; WBI). Grade 2-3 induration was observed in 5% (PBI) and 10% (WBI) of the patients. A dose-response relationship was established between irradiated breast volume and frequency of breast induration. From the model, 5% and 10% risks of breast induration were observed for ≥40 Gy delivered to CTVp_breast volumes of 177 mL (95%CI, 94-260 mL) and 426 mL (95%CI, 286-567 mL), respectively. CONCLUSION The frequency of breast induration increased significantly with increasing irradiated breast volume, strongly favouring small volumes and PBI. Thus, treated breast volume - not the breast size itself - is the risk factor for induration. This is the first report directly linking the 40 Gy irradiated breast volume to breast induration.

KM 提取结果

0 个 Figure · 0 个 KM 面板

尚未提取到 KM 面板。