Ultrasound-assisted carbon nanoparticle suspension mapping versus dual tracer-guided sentinel lymph node biopsy in patients with early breast cancer (ultraCars): phase III randomized clinical trial.

Liulu Zhang, Minyi Cheng, Yingyi Lin, Junsheng Zhang, Bo Shen, Yuanqi Chen, Ciqiu Yang, Mei Yang, Teng Zhu, Hongfei Gao, Fei Ji, Jieqing Li, Kun Wang

Br J Surg 109(12) 1232-1238

PMID36074703
PMCIDPMC10364740
DOI10.1093/bjs/znac311
发表日期2022-09-08
入排依据:The study is a phase III randomized trial in oncology with human subjects and original results, but it is excluded because the primary endpoint is a diagnostic performance metric (SLN identification rate), not a time-to-event efficacy endpoint. The intervention is a procedural/diagnostic technique, not a drug intervention for treatment efficacy.
摘要

摘要

BACKGROUND: Appropriate tracing methods for sentinel lymph node biopsy (SLNB) play a key role in accurate axillary staging. This prospective, non-inferiority, phase III RCT compared the feasibility and diagnostic performance of ultrasound-assisted carbon nanoparticle suspension (CNS) mapping with dual tracer-guided SLNB in patients with early breast cancer. METHODS: Eligible patients had primary breast cancer without nodal involvement (cN0), or had clinically positive lymph nodes (cN1) that were downstaged to cN0 after neoadjuvant chemotherapy. Patients were randomly assigned (1 : 1) to undergo either ultrasound-assisted CNS sentinel lymph node (SLN) mapping (UC group) or dual tracer-guided mapping with CNS plus indocyanine green (ICG) (GC group). The primary endpoint was the SLN identification rate. RESULTS: Between 1 December 2019 and 30 April 2021, 330 patients were assigned randomly to the UC (163 patients) or GC (167 patients) group. The SLN identification rate was 94.5 (95 per cent c.i. 90.9 to 98.0) per cent in the UC group and 95.8 (92.7 to 98.9) per cent in the GC group. The observed difference of -1.3 (-5.9 to 3.3) per cent was lower than the prespecified non-inferiority margin of 6 per cent (Pnon-inferiority = 0.024). No significant difference was observed in metastatic node rate (30.5 versus 24.4 per cent; P = 0.222), median number of SLNs harvested (3 (range 1-7) versus 3 (1-8); P = 0.181), or duration of surgery (mean(s.d.) 7.53(2.77) versus 7.63(3.27) min; P = 0.316) between the groups. Among the subgroup of patients who had undergone neoadjuvant treatment, the SLN identification rate was 91.7 (82.2 to 100) per cent in the UC group and 90.7 (81.7 to 99.7) per cent in the GC group. CONCLUSION: The diagnostic performance of ultrasound-assisted CNS mapping was non-inferior to that of dual tracer-guided SLN mapping with CNS plus ICG in patients with early breast cancer. REGISTRATION NUMBER: NCT04951245 (http://www.clinicaltrials.gov).

KM 提取结果

0 个 Figure · 0 个 KM 面板

尚未提取到 KM 面板。